Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise
conference contribution
posted on 2016-03-23, 10:29 authored by Abdullah Alzahrani, Sijung HuSijung Hu, Vicente Azorin-Peris, Laura BarrettLaura Barrett, Dale EsligerDale Esliger, Matthew Hayes, Shafique Akbare, Jerome Achart, Sylvain KuochThis study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p < 0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to+18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.
Funding
The authors would like to acknowledge Loughborough University and Taif University for supporting this research.
History
School
- Mechanical, Electrical and Manufacturing Engineering
Published in
Conference on Design and Quality for Biomedical Technologies VIII Design and Quality for Biomedical Technologies VIIIVolume
9315Pages
? - ? (14)Citation
ALZAHRANI, A. ... et al., 2015. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise. Proceedings of SPIE, 9315, DOI: 10.1117/12.2076582.Publisher
© SPIEVersion
- VoR (Version of Record)
Publisher statement
This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/Publication date
2015Notes
This document is Closed Access.ISSN
0277-786XeISSN
1996-756XPublisher version
Language
- en