Loughborough University
Browse
Integrated system for temperature controlled fast protein liquid chromatography_II Optimized adsorbents and single column operation_LBORO.pdf (934.45 kB)

Integrated system for temperature-controlled fast protein liquid chromatography. II. Optimized adsorbents and 'single column continuous operation'

Download (934.45 kB)
journal contribution
posted on 2015-07-13, 13:29 authored by Ping Cao, Tobias K.H. Muller, Benedikt Ketterer, Staphanie Ewert, Eirini Theodosiou, Owen R.T. Thomas, Matthias Franzreb
Continued advance of a new temperature-controlled chromatography system, comprising a column filled with thermoresponsive stationary phase and a travelling cooling zone reactor (TCZR), is described. Nine copolymer grafted thermoresponsive cation exchangers (thermoCEX) with different balances of thermoresponsive (N-isopropylacrylamide), hydrophobic (N-tert-butylacrylamide) and negatively charged (acrylic acid) units were fashioned from three cross-linked agarose media differing in particle size and pore dimensions. Marked differences in grafted copolymer composition on finished supports were sourced to base matrix hydrophobicity. In batch binding tests with lactoferrin, maximum binding capacity (q max) increased strongly as a function of charge introduced, but became increasingly independent of temperature, as the ability of the tethered copolymer networks to switch between extended and collapsed states was lost. ThermoCEX formed from Sepharose CL-6B (A2), Superose 6 Prep Grade (B2) and Superose 12 Prep Grade (C1) under identical conditions displayed the best combination of thermoresponsiveness (q max,50°C/q max,10°C ratios of 3.3, 2.2 and 2.8 for supports 'A2', 'B2' and 'C1' respectively) and lactoferrin binding capacity (q max,50°C ~56, 29 and 45mg/g for supports 'A2', 'B2' and 'C1' respectively), and were selected for TCZR chromatography. With the cooling zone in its parked position, thermoCEX filled columns were saturated with lactoferrin at a binding temperature of 35°C, washed with equilibration buffer, before initiating the first of 8 or 12 consecutive movements of the cooling zone along the column at 0.1mm/s. A reduction in particle diameter (A2→B2) enhanced lactoferrin desorption, while one in pore diameter (B2→C1) had the opposite effect. In subsequent TCZR experiments conducted with thermoCEX 'B2' columns continuously fed with lactoferrin or 'lactoferrin+bovine serum albumin' whilst simultaneously moving the cooling zone, lactoferrin was intermittently concentrated at regular intervals within the exiting flow as sharp uniformly sized peaks. Halving the lactoferrin feed concentration to 0.5mg/mL, slowed acquisition of steady state, but increased the average peak concentration factor from 7.9 to 9.2. Finally, continuous TCZR mediated separation of lactoferrin from bovine serum albumin was successfully demonstrated. While the latter's presence did not affect the time to reach steady state, the average lactoferrin mass per peak and concentration factor both fell (respectively from 30.7 to 21.4mg and 7.9 to 6.3), and lactoferrin loss in the flowthrough between elution peaks increased (from 2.6 to 12.2mg). Fouling of the thermoCEX matrix by lipids conveyed into the feed by serum albumin is tentatively proposed as responsible for the observed drops in lactoferrin binding and recovery.

Funding

This work was funded by the European Framework 7 large scale integrating collaborative project ‘Advanced Magneticnano-particles Deliver Smart Processes and Products for Life’(MagPro2Life, CP-IP 229335-2).

History

School

  • Aeronautical, Automotive, Chemical and Materials Engineering

Department

  • Chemical Engineering

Published in

Journal of Chromatography A

Citation

CAO, P. ... et al, 2015. Integrated system for temperature-controlled fast protein liquid chromatography. II. Optimized adsorbents and 'single column continuous operation'. Journal of Chromatography A, 1403, pp. 118-131.

Publisher

© Elsevier B.V

Version

  • AM (Accepted Manuscript)

Publisher statement

This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/

Publication date

2015

ISSN

0021-9673

eISSN

1873-3778

Language

  • en