A comparison of indoor pollution using different ventilation methods: A case study

Download (2.91 MB)
conference contribution
posted on 2022-10-07, 11:54 authored by Salam Al-SammanSalam Al-Samman, Mahroo EftekhariMahroo Eftekhari, Vanda DimitriouVanda Dimitriou, Daniel Coakley, Charalampos Angelopoulos

One of the essential aspects of healthy buildings is the air quality that people breathe indoors, as it directly impacts their comfort, health, and well-being. Achieving an acceptable indoor air quality (IAQ) has become an essential design objective for newly constructed and renovated buildings as well as for the operational system in existing buildings. The COVID-19 pandemic, which began in 2019, highlighted the need for better IAQ. The quality of indoor air space is not only affected by ambient or external pollution but also by indoor sources and inadequate ventilation. For instance, the build-up of pollutants may differ for the same space due to the ventilation method. This paper uses a case study of an open-plan office in Loughborough, UK, simulated under two ventilation schemes, mechanical ventilation (MV) and natural ventilation (NV), for the same weather file to diagnose and examine the difference in the IAQ. The results of the simulations were compared with monitored data using an IAQ sensor located in the centre of the open-plan office. The air parameters measured were indoor temperature (Ta), relative humidity (RH), carbon dioxide (CO2), formaldehyde (CH2O) and particulate matter (PM2.5). It was found that the average CO2 levels were better by 10% under MV than in NV because higher ventilation rates were achieved during occupied hours. The average PM2.5 was twofold better under NV than MV, as well as CH2O was also better under NV than MV by 26% in the simulated scenarios. The open-plan office was ventilated at all times under NV; unlike in MV, the air handling unit was only operating during the occupied hours, which contributed to better IAQ. The simulation results for this study revealed that both mechanical and natural ventilation could achieve acceptable IAQ for this specific case study and location. The ventilation control strategy is the manipulator of jeopardising the IAQ in the space. 

History

School

  • Architecture, Building and Civil Engineering

Published in

CLIMA 2022 Conference Proceedings

Source

CLIMA 2022 The 14th REHVA HVAC World Congress

Publisher

TU Delft Open

Version

  • VoR (Version of Record)

Rights holder

© The Authors

Publisher statement

This is an Open Access article of a conference paper presented at the 2022: CLIMA 2022 The 14th REHVA HVAC World Congress and published by TU Delft Open.

Publication date

2022-05-21

Copyright date

2022

Language

  • en

Location

Rotterdam, The Netherlands

Event dates

22nd May 2022 - 25th May 2022

Depositor

Prof Mahroo Eftekhari. Deposit date: 30 September 2022

Usage metrics

    Loughborough Publications

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC