The highly concentrated fluoride in groundwater has been observed in the confined aquifers of the alluvial sediments in the
Chiang Mai Basin. Nanofiltration process was applied to the control of fluoride exposure to the local residents, who have
suffered from serious dental and osteal fluorosis.
The membrane plants used polyamide nanofilters, which were found to have different fluoride removal rates depending
on pH of feed waters. Although fluoride removal rates were high at neutral to basic pH, calcium carbonate scale on the
membrane surface was estimated to be the major problem in membrane fouling. Optimum combination of pretreatment in
the membrane plant was evaluated through the investigation on the groundwater quality and the operational conditions.
History
School
Architecture, Building and Civil Engineering
Research Unit
Water, Engineering and Development Centre (WEDC)
Published in
WEDC Conference
Citation
MATSUI, Y. ... et al, 2006. Application of nanofiltration processes to fluoride removal from groundwaters in the Chiang Mai Basin. IN: Fisher, J. (ed). Sustainable development of water resources, water supply and environmental sanitation: Proceedings of the 32nd WEDC International Conference, Colombo, Sri Lanka, 13-17 November 2006, pp. 459-466.