posted on 2010-06-03, 13:16authored byHazel J. Scott, Alastair Gale, Sue Hill
A radiographic ‘false negative’ or a case which has been ‘missed’ can be categorised in terms of errors of search (where
gaze does not fall upon the abnormality); detection (a perceptual error where the abnormality may be physically ‘seen’
but remains undetected) and misinterpretation (a perceptual error whereby an abnormality, although detected, is not
deemed worthy of further assessment). This study aims to investigate perceptual errors in mammographic film-reading
and will focus on the later of the two error types, namely errors of misinterpretation and errors of non-detection.
Previous research has shown, on a self-assessment scheme of recent and difficult breast-screening cases, that certain
feature types are susceptible to errors of misinterpretation and others to errors of non-detection. This self assessment
scheme, ‘PERFORMS’ (Personal Performance in Mammographic Screening), is undertaken by the majority (at present
over 90%) of breast-screening mammographers in the UK Breast Screening Programme. The scheme is completed biannually
and confidentially and participants receive immediate and detailed feedback on their performance. Feedback
from the scheme includes information detailing their false negative decisions including case classifications (benign or
malignant), feature type (masses, calcification, asymmetries, architectural distortions and others) and case perception
error (percentage of misinterpretation and percentage of non-detection). Results from a recent round of PERFORMS
(n=506), revealed that certain feature types had significantly higher percentages of error overall (including architectural
distortion and asymmetries), and that these feature types also showed significant differences for error type. Implications
for real-life screening practice were explored using real-life self-reported data on years of screening experience.
History
School
Science
Department
Computer Science
Citation
SCOTT, H.J., GALE, A.G. and HILL, S., 2008. How are false negative cases perceived by mammographers? Which abnormalities are misinterpreted and which go undetected? IN: Sahiner, B. and Manning, D.J. (eds.). Medical Imaging 2008: Image Perception, Observer Performance, and Technology Assessment. Proceedings of SPIE 6917, 691713.
Copyright 2008 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. This paper can also be found at: http://dx.doi.org/10.1117/12.771137