Sensor location methodology for improved IEQ monitoring in working environments
In the current era, sensors in buildings have become an essential requirement for wide applications such as monitoring indoor air quality (IAQ), thermal and environmental conditions, controlling building heating, ventilation, and air-conditioning systems (HVAC). To accurately control the IAQ for all areas in the indoor space, it is necessary to obtain considerable data from different locations in the space for more precision. The airflow in a room is not uniform, which raises the question of where the environmental sensor should be positioned with regard to optimum performance of IAQ and thermal comfort. This paper uses a case study of an open-plan office in Loughborough, UK, to assess the indoor climate conditions from real-time measurements from several sensors placed in different locations in the office and investigates the potency of using ventilation effectiveness (Ez), one of the IAQ relative indicators, as a preference to locate environmental sensors. The air parameters measured by the sensors are indoor temperature (ta), relative humidity (RH), carbon dioxide (CO2), total volatile organic compounds (tVOCs), formaldehyde (CH2O) and particulate matter (PM2.5 and PM10). Computational fluid dynamics (CFD) simulations were conducted to identify the areas in the office with low Ez evaluated using the age-of-air. Results showed that the measurement of RH and CO2 levels were marginally different between the sensors. A larger difference was found for temperature, assuming local heat sources significantly influenced the measured temperatures. Also, the calculated Ez from the measured data of each sensor was found to be different for each sensor location. The results from field measurements and CFD simulations can support decision making regarding the position of environmental sensors and the collection of indoor climate data in open-plan offices.
History
School
- Architecture, Building and Civil Engineering
Published in
IAQ 2020 Conference ProceedingsSource
Conference on Indoor Environmental Quality Performance Approaches (IAQ)Publisher
ASHRAEVersion
- VoR (Version of Record)
Rights holder
© ASHRAEPublisher statement
© 2020, ASHRAE (www.ashrae.org). Published in IAQ 2020 Conference Proceedings. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. All other outside requests for use must be directed to ASHRAE, https://www.ashrae.org/permissions.Acceptance date
2022-09-05Publication date
2022-05-04Copyright date
2022Publisher version
Language
- en