posted on 2008-10-30, 12:47authored byJ.D. Andrews, J.M. Morgan
This paper describes the digraph method of fault tree construction and its application to the process stream of a butane vaporiser. It is shown that an accurate, well-structured fault tree can be produced for a process system which incorporates a number of control loops.
Funding
British Gas R & D
History
School
Aeronautical, Automotive, Chemical and Materials Engineering
Department
Aeronautical and Automotive Engineering
Citation
ANDREWS, J.D. and MORGAN, J.M., 1986. Application of the digraph method of fault tree construction to process plant. Reliability Engineering, 14 (2), pp. 85-106 [doi:10.1016/0143-8174(86)90045-4]