Damage in extrusion additive manufactured biomedical polymer: effects of testing direction and environment during cyclic loading

Download (3.26 MB)
journal contribution
posted on 2021-03-31, 14:58 authored by Amirpasha Moetazedian, Andy GleadallAndy Gleadall, Elisa MeleElisa Mele, Vadim SilberschmidtVadim Silberschmidt
Although biodegradable polymers were widely researched, this is the first study considering the effect of combined testing environments and cyclic loading on the most important aspect related to additive manufacturing: the interfacial bond between deposited layers. Its results give confidence in applicability of the material extrusion additive manufacturing technology for biomedical fields, by demonstrating that the interface behaves in a manner similar to that of the bulk-polymer material. To do this, especially designed tensile specimens were used to analyse the degradation of 3D-printed polymers subjected to constant-amplitude and incremental cyclic loads when tested in air at room temperature (control) and submerged at 37 °C (close to in-vivo conditions). The mechanical properties of the interface between extruded filaments were compared against the bulk material, i.e. along filaments. In both cases, cyclic loading caused only a negligible detrimental effect compared to non-cyclic loading (less than 10 % difference in ultimate tensile strength), demonstrating the suitability of using 3D-printed components in biomedical applications, usually exposed to cyclic loading. For cyclic tests with a constant loading amplitude, larger residual deformation (>100 % greater) and energy dissipation (>15 % greater) were found when testing submerged in solution at 37 °C as opposed to in laboratory conditions (air at room temperature), as used by many studies. This difference may be due to plasticisation effects of water and temperature. For cyclic tests with incrementally increasing loading amplitudes, the vast majority of energy dissipation happened in the last two cycles prior to failure, when the polymer approached the yield point. The results demonstrate the importance of using an appropriate methodology for biomedical applications; otherwise, mechanical properties may be overestimated.

History

School

  • Aeronautical, Automotive, Chemical and Materials Engineering
  • Mechanical, Electrical and Manufacturing Engineering

Department

  • Materials

Published in

Journal of the Mechanical Behavior of Biomedical Materials

Volume

118

Publisher

Elsevier

Version

  • AM (Accepted Manuscript)

Rights holder

© Elsevier

Publisher statement

This paper was accepted for publication in the journal Journal of the Mechanical Behavior of Biomedical Materials and the definitive published version is available at https://doi.org/10.1016/j.jmbbm.2021.104397.

Acceptance date

2021-02-11

Publication date

2021-02-20

Copyright date

2021

ISSN

1751-6161

eISSN

1878-0180

Language

  • en

Depositor

Andy Gleadall. Deposit date: 29 March 2021

Article number

104397

Usage metrics

    Loughborough Publications

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC