Improving umbilical cord blood processing to increase total nucleated cell count yield and reduce cord input wastage by managing the consequences of input variation
posted on 2015-01-14, 14:14authored byMay W. Naing, Daniel A. Gibson, Paul Hourd, Susana G. Gomez, Roger B.V. Horton, Joel Segal, David Williams
BACKGROUND AIMS: With the rising use of umbilical cord blood (UCB) as an alternative source of hematopoietic stem cells, storage inventories of UCB have grown, giving rise to genetically diverse inventories globally. In the absence of reliable markers such as CD34 or counts of colony-forming units, total nucleated cell (TNC) counts are often used as an indicator of potency, and transplant centers worldwide often select units with the largest counts of TNC. As a result, cord blood banks are driven to increase the quality of stored inventories by increasing the TNC count of products stored. However, these banks face challenges in recovering consistent levels of TNC with the use of the standard protocols of automated umbilical cord processing systems, particularly in the presence of input variation both of cord blood volume and TNC count, in which it is currently not possible to process larger but useable UCB units with consequent losses in TNC. METHODS: This report addresses the challenge of recovering consistently high TNC yields in volume reduction by proposing and validating an alternative protocol capable of processing a larger range of units more reliably. RESULTS: This work demonstrates improvements in plastic ware and tubing sets and in the recovery process protocol with consequent productivity gains in TNC yield and a reduction in standard deviation. CONCLUSIONS: This work could pave the way for cord blood banks to improve UCB processing and increase efficiency through higher yields and lower costs.
Funding
This work was funded via the EPRSC Centre for
Innovative Manufacturing in Regenerative Medicine
History
School
Mechanical, Electrical and Manufacturing Engineering
Published in
Cytotherapy
Volume
17
Issue
1
Pages
58 - 67
Citation
NAING, M.W. ... et al., 2015. Improving umbilical cord blood processing to increase total nucleated cell count yield and reduce cord input wastage by managing the consequences of input variation. Cytotherapy, 17 (1), pp. 58 - 67.
Publisher
International Society for Cellular Therapy. Published by Elsevier Inc.
Version
VoR (Version of Record)
Publisher statement
This work is made available according to the conditions of the Creative Commons Attribution 3.0 Unported (CC BY 3.0) licence. Full details of this licence are available at: http://creativecommons.org/licenses/by/3.0/
Publication date
2015
Notes
This is an Open Access Article (CC-BY 3.0). It is published by Elsevier as Open Access at: http://dx.doi.org/10.1016/j.jcyt.2014.09.003