Loughborough University
Browse
- No file added yet -

Lobar ventilation in patients with COPD assessed with the full-scale airway network flow model and xenon-enhanced dual-energy CT

Download (2.36 MB)
journal contribution
posted on 2020-12-03, 11:06 authored by Minsuok KimMinsuok Kim, Ozkan Doganay, Hye Jeon Hwang, Joon Beom Seo, Fergus V Gleeson
Lobar ventilation in patients with chronic obstructive pulmonary disease computed with a full-scale airway network flow model correlated with xenon-enhanced dual-energy CT gas ventilation images.

Background
The full-scale airway network (FAN) flow model shows excellent agreement with limited functional imaging data but requires further validation prior to clinical use.

Purpose
To validate the ventilation distributions computed with the FAN flow model with xenon ventilation from xenon-enhanced dual-energy (DE) CT in participants with chronic obstructive pulmonary disease (COPD).

Materials and Methods
In this prospective study, the FAN model extracted structural data from xenon-enhanced DE CT images of men with COPD scanned between June 2012 and July 2013 to compute gas ventilation dynamics. The ventilation distributions on the middle cross-section plane, percentage lobar ventilation, and ventilation heterogeneity quantified by the coefficient of variation (CV) were compared between xenon-enhanced DE CT imaging and the FAN model. The relationship between the ventilation parameters with the densitometry and pulmonary function test results was demonstrated. The agreements and correlations between the parameters were measured using the concordance correlation coefficient and the Pearson correlation coefficient.

Results
Twenty-two men with COPD (mean age, 67 years ± 7 [standard deviation]) were evaluated. The percentage lobar ventilation computed with FAN showed a strong positive correlation with xenon-enhanced DE CT data (r = 0.7, P < .001). Ninety-five percent of lobar ventilation CV differences lay within 95% confidence intervals. Correlations of the percentage lobar ventilation were negative for percentage emphysema (xenon-enhanced DE CT: r = -0.38, P < .001; FAN: r = -0.23, P = .02) but were positive for percentage normal tissue volume (xenon-enhanced DE CT: r = 0.78, P < .001; FAN: r = 0.45, P < .001). Lung CVs of FAN revealed negative correlations with the spirometry results (CVFAN vs percentage predicted forced expiratory volume in 1 second: r = -0.75, P < .001; CVFAN vs ratio of forced expiratory volume in 1 second to forced vital capacity: r = -0.67, P < .001).

Conclusion
The full-scale airway network modeled lobar ventilation in patients with chronic obstructive pulmonary disease correlated with the xenon-enhanced dual-energy CT imaging data.

Funding

Cancer Research UK (Grant Number: C5255)

The Engineering and Physical Sciences Research Council (EPSRC) in the UK (Grant Number: A16466)

NIHR Biomedical Research Centre, Oxford.

History

School

  • Mechanical, Electrical and Manufacturing Engineering

Published in

Radiology

Volume

298

Issue

1

Pages

201 - 209

Publisher

Radiological Society of North America (RSNA)

Version

  • VoR (Version of Record)

Rights holder

© RSNA

Publisher statement

This paper was published in the journal Radiology and is available at https://doi.org/10.1148/radiol.2020202485.

Acceptance date

2020-10-01

Publication date

2020-11-24

Copyright date

2020

ISSN

0033-8419

eISSN

1527-1315

Language

  • en

Depositor

Dr Minsuok Kim. Deposit date: 2 December 2020

Usage metrics

    Loughborough Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC