posted on 2012-07-12, 11:35authored byChristian Christodoulou, Chris GoodierChris Goodier, Simon Austin, John Webb, Gareth K. Glass
A range of methods exist to assess the condition of steel reinforcement in concrete. The analysis of the transient response to a small perturbation has been employed successfully in laboratories to assess corrosion. This work examines a simplified method for the application of transientanalysis to in situ reinforcedconcrete structures. The complex analysis has been simplified and undertaken with the use of common spreadsheet packages. The results illustrate that transient response analysis is a viable technique for use on site and appears to provide a more accurate representation of steel corrosion current densities at very low values than polarisation resistance.
History
School
Architecture, Building and Civil Engineering
Research Unit
Centre for Innovative and Collaborative Engineering (CICE)
Citation
CHRISTODOULOU, C. ... et al., 2012. On-site transient analysis for the corrosion assessment of reinforced concrete. Corrosion Science, 62, pp. 176–183