Performance evaluation of a mechanically ventilated heat recovery (MVHR) system as part of a series of UK residential energy retrofit measures

journal contribution
posted on 2016-01-06, 13:32 authored by J. White, Mark Gillott, C.J. Wood, Dennis Loveday, Keyur Vadodaria
This study involves a detailed analysis of a mechanically ventilated heat recovery (MVHR) system installed as a case study retrofit project in a UK test dwelling. Comparisons of predicted and in situ performance are made through the calculation of a theoretical and practical heat loss coefficient value (HLC). Analysis revealed underperformance in the installed MVHR system, as compared to predicted data. Issues were identified in the installation and function of the control unit and ductwork. Improvement work enabled the system to function more closely to optimum performance levels. However, discrepancies still existed between the predicted and actual HLC values, which were largely accounted for through theoretical heat loss calculations attributable to slight imbalances within the system supply and extract rates. When normalised, the data still showed an unaccounted heat loss of approximately 6 W/K in both MVHR tests. The study reinforces the need for high quality MVHR installation and commissioning work, which is critical to ensure that a system can perform to the optimum levels specified in manufacturer literature. Education and training throughout the supply chain is essential in achieving this, as system inefficiencies can lead to unnecessary heat losses resulting from increased levels of air infiltration or leakage.

Funding

This work forms part ofthe E.On funded Retrofit Research House Project and the CALEBRE Project which is funded by the Research Councils UK and E.ON.

History

School

  • Architecture, Building and Civil Engineering

Published in

Energy and Buildings

Volume

110

Pages

220 - 228

Citation

WHITE, J. ... et al., 2016. Performance evaluation of a mechanically ventilated heat recovery (MVHR) system as part of a series of UK residential energy retrofit measures. Energy and Buildings, 110, pp. 220 - 228.

Publisher

© Elsevier B.V.

Version

  • AM (Accepted Manuscript)

Publisher statement

This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/

Publication date

2015-10-28

Notes

Closed access until 28 October 2016

ISSN

0378-7788

Language

  • en