Blood osmolality is considered the gold standard hydration assessment, but has limited application for technical and invasive reasons. Paired antecubital-venous blood and fingertip-capillary blood were collected pre- and 30 min post-drinking 600 mL water in 55 male/female participants. No bias (0.2 mOsmo/kg, limits of agreement = −2.5 to 2.8 mOsmo/kg) was found between sampling methods, with high linear correlation (Spearman’s r = 0.95, P < 0.001). Capillary blood sampling offers an accurate less-invasive method for determining serum osmolality than venous blood sampling.
This article is published by Canadian Science Publishing. Permission for reuse (free in most cases) can be obtained from copyright.com - https://marketplace.copyright.com/rs-ui-web/mp.