Purpose
The physiological strain index (PSI) was developed to assess individuals’ heat strain, yet evidence supporting its use to identify individuals at potential risk of reaching a thermal tolerance limit (TTL) is limited. The aim of this study was to assess whether PSI can identify individuals at risk of reaching a TTL.
Methods
Fifteen females and 21 males undertook a total of 136 trials, each consisting of two 40–60 minute periods of treadmill walking separated by ~ 15 minutes rest, wearing permeable or impermeable clothing, in a range of climatic conditions. Heart rate (HR), skin temperature (Tsk), rectal temperature (Tre), temperature sensation (TS) and thermal comfort (TC) were measured throughout. Various forms of the PSI-index were assessed including the original PSI, PSIfixed, adaptive-PSI (aPSI) and a version comprised of a measure of heat storage (PSIHS). Final physiological and PSI values and their rate of change (ROC) over a trial and in the last 10 minutes of a trial were compared between trials completed (C, 101 trials) and those terminated prematurely (TTL, 35 trials).
Results
Final PSIoriginal, PSIfixed, aPSI, PSIHS did not differ between TTL and C (p > 0.05). However, differences between TTL and C occurred in final Tsk, Tre–Tsk, TS, TC and ROC in PSIfixed, Tre, Tsk and HR (p < 0.05).
Conclusion
These results suggest the PSI, in the various forms, does not reliably identify individuals at imminent risk of reaching their TTL and its validity as a physiological safety index is therefore questionable. However, a physiological-perceptual strain index may provide a more valid measure.
Funding
European Commission for project funding FP7-NMP-2008SME-2, Proj. No. 229042: PROSPIE—Protective Responsive Outer Shell for People in Industrial Environments.
This is an Open Access Article. It is published by Springer under the Creative Commons Attribution 4.0 Unported Licence (CC BY). Full details of this licence are available at: http://creativecommons.org/licenses/by/4.0/